The enduring HDD temperature surveillance guarantees an alarm reaction in case the
threshold value is exceeded.
There may be several reasons for HDD temperature excess:
- Exceedance of the max. tolerable ambient temperature (40°C), e.g. upon installation in
an electrical cabinet with inadequate ventilation
- After-effect upon fan failure
-HDD defect
3.11.2 HDD TEMP.
50
WARNING SETUP MENU
FAN FAULT BUZZER ENABLE
HDD TEMP. ALARM OUTPUT 1
NO HDD ALARM DURATION PERMANENT
HDD FULL NETWORK ALARM NO
EMAIL NO
STOP RECORD YES
(1) BUZZER: By selecting “ENABLE”, the buzzer is activated upon HDD temperature excess.
(2) ALARM OUTPUT: Output relay activation.
1 – Output relay 1 ~ 4 (selection) switches upon alarm.
NONE – no output relay reaction upon alarm.
(3) ALARM DURATION: PERMANENT - This value cannot be changed, alarm is
automatically switched off after problem has been solved.
(4) NETWORK ALARM:
YES: Network alarm activated (for settings refer to NETWORK menu)
Network alarm reception requires optional PowerCon software.
NO: No network alarm transmission
(5) EMAIL:
YES: Alarm email transmission (for settings refer to NETWORK menu).
NO: No email alarm transmission.
(6) STOP RECORD
YES: Recording process is stopped to avoid further temperature rise
and HDD damage.
NO: Recording process continues.